Home/Products/Filter Housings/All-PFA Filter Housing, Union-Nut Bowl
All-PFA Filter Housing, Union-Nut Bowl

All-PFA Filter Housing, Union-Nut Bowl

Product ID: all-pfa-filter-housing-union-nut|PFA

An all-PFA single-cartridge housing: a PFA bowl and head held together by a PVDF bowl nut, with a PFA-encapsulated FKM (Viton) O-ring, so nothing metallic touches the fluid. It takes a 5", 10" or 20" cartridge, with 3/4" or 1" inlet and outlet in flare or insert-bead fittings and a 1/2" flare vent. Cartridges are sold separately.

  • PFA bowl, head, ports and vent plug: no metal on the wetted surface
  • The PVDF bowl nut sits outside the flow path and never touches the chemical
  • PFA-encapsulated FKM (Viton) O-ring
  • Takes a single 5", 10" or 20" cartridge
  • 3/4" or 1" ports in flare or insert-bead style; 1/2" flare vent
Inquire About This ProductAsk on LINE

Add us on WeChat

JIUNYUAN WeChat QR code
  • On a computer: open WeChat on your phone, tap Scan, and scan the QR code above.
  • On a phone: save or screenshot this image, then open Scan in WeChat and pick it from Album (top right).
  • Viewing this page inside WeChat: long-press the QR code to scan it.
← Back to Category
Cartridge capacity × length
Single 5", 10" or 20" cartridge
Inlet / outlet connections
3/4" or 1" inlet / outlet
Body material
PFA bowl and head
Semiconductor wet-process chemical filtration
Ultrapure water (UPW) point-of-use filtration
Chemical distribution system (CDS) branch lines
Display and solar wet processing
High-purity acid, caustic and solvent lines
Chemical filtration inside process tools
Body material
PFA bowl and head; PVDF bowl nut; PFA port nuts and vent plug
Wetted materials
The flow path sees only PFA (bowl, head, ports, vent plug) and the PFA jacket of the O-ring; the PVDF bowl nut sits outside the flow path as a non-wetted part.
Seals / O-rings
PFA-encapsulated FKM (Viton) O-ring
Cartridge capacity × length
Single 5", 10" or 20" cartridge; the cartridge interface is confirmed at enquiry
Inlet / outlet connections
3/4" or 1" inlet / outlet; flare or insert-bead fittings
Closure type
The bowl is held to the head by a PVDF bowl nut: unscrew the nut and lift the bowl off to change the cartridge. A dedicated wrench and a clip for inverted mounting are available as accessories.
Vent & drain
1/2" flare vent with a PFA goblet-style plug
Regulatory & validation
No metal on the wetted surface, so it suits high-purity chemical and UPW lines; pressure–temperature ratings and outline dimensions are supplied on enquiry.
Cartridge lengthFlare fitting part no.Insert-bead part no.
5"JY-HSC3-05-F07-P / F10-PJY-HSC3-05-B07-P / B10-P
10"JY-HSC3-10-F07-P / F10-PJY-HSC3-10-B07-P / B10-P
20"JY-HSC3-20-F07-P / F10-PJY-HSC3-20-B07-P / B10-P

← Swipe to see all columns

07 = 3/4", 10 = 1"; P = PFA-encapsulated FKM (Viton) O-ring. The vent is always a 1/2" flare. Ask our sales team for the pressure–temperature ratings, outline dimensions and cartridge interface when enquiring.

Note: actual compatibility and service life depend on chemical concentration, temperature, flow, differential pressure, upstream contamination load and housing design. Validate under your real process conditions.

Example part number
JY
-HSC3
-10
-F10
-P
JY
JIUNYUAN Technology
HSC3
All-PFA bowl and head with a PVDF bowl nut; no metal on the wetted surface
10
Single 10" cartridge
F10
1" flare face-seal
P
PFA-encapsulated FKM (Viton) O-ring
Build your part number

Pick each option and the part number assembles itself; copy it into your RFQ or verify it with the site search.

Part-number structureJY-HSC3-01-02-03
JY-HSC3-10-F10-PVerify with site search
Selectable options by segment
01

Capacity

CodeSpecification
05Single 5" cartridge
10Single 10" cartridge
20Single 20" cartridge
02

Inlet / outlet

CodeSpecification
F073/4" flare face-seal
F101" flare face-seal
B073/4" insert-bead type
B101" insert-bead type

Choose the port size and fitting style together; the vent is always a 1/2" flare and is not coded. Confirm that the insert-bead fittings match your existing tube fittings when enquiring.

03

O-ring material

CodeSpecification
PPFA-encapsulated FKM (Viton) O-ring

Housings and cartridges are ordered separately. Confirm that the cartridge end-cap style matches the housing before selecting. The dedicated wrench and the inverted-mounting clip are separate accessories outside the part number; just mention them when requesting a quote.

Not every combination is a stock item; uncommon combinations are made to order. Confirm with JIUNYUAN sales before ordering.

Where it fits

This single-cartridge housing is PFA throughout: the bowl, head, port nuts and vent plug are all PFA, so there is no metal anywhere on the wetted surface. It is meant for high-purity chemical and UPW lines in semiconductor, display and solar wet processing, as the housing for point-of-use (POU) or branch-line filtration.

The construction is the familiar bowl-and-nut design: the cartridge sits on the head, the bowl goes over it, and a PVDF bowl nut locks the bowl to the head. The nut sits outside the flow path and never touches the chemical, so it can be made from PVDF, which is stiffer than PFA and deforms less under tightening.

Key characteristics

  • All-PFA wetted surface: bowl, head, ports and vent plug are PFA; the O-ring is PFA-encapsulated FKM (Viton), so the chemical only meets the PFA jacket while the FKM inside provides the elasticity.
  • Three lengths: takes a single 5", 10" or 20" cartridge; choose the length to suit the line flow.
  • Two fitting styles: 3/4" or 1" inlet and outlet in flare or insert-bead fittings, to match the tube fittings already on site.
  • Vent and accessories: a 1/2" flare vent with a PFA goblet-style plug; a dedicated wrench for the bowl nut and a clip for inverted mounting are available as accessories.

Choosing between options

This site carries three housings with a fully fluoropolymer wetted surface; they differ in construction and connections:

ItemThis housing (JY-HSC3)Fool-proof lock (JY-HSC1)Lined Tri-Clamp (JY-HSC2)
ConstructionPFA bowl + PVDF bowl nutInjection-moulded all-PFA, fool-proof locking ring316L stainless lined with PFA
ConnectionsFlare or insert-bead, 3/4" or 1"Flaretek, Super Pillar or S300, 3/4" or 1"Tri-Clamp
Cartridge lengths5", 10", 20"5", 10", 20", 30"5", 10", 20"
Why choose itFamiliar bowl-and-nut design, with an insert-bead fitting optionThe operator never touches the cartridge and cannot fit it the wrong way roundYou need the strength of a metal shell and sanitary connections

See the PFA high-purity filter housing and the PFA-lined Tri-Clamp filter housing and vent breather for the other two. Cartridges are ordered separately, and the cartridge interface of this housing is confirmed at enquiry; fluoropolymer lines normally take a fluoropolymer cartridge such as the semiconductor-grade all-PTFE cartridge. For material selection, see the chemical compatibility guide.

Operation & change-out

The housing pressure rating is what the shell can hold, not the cartridge's differential-pressure limit, and both must suit the line conditions. Ask our sales team for this housing's pressure–temperature ratings and outline dimensions when enquiring; check hot chemicals in particular, because PFA softens as temperature rises and the allowable pressure falls with it.

To change the cartridge, depressurise and drain, unscrew the PVDF bowl nut with the dedicated wrench and lift off the bowl. After fitting the new cartridge, check the O-ring for scratches or chemical crystals before tightening the nut again. At start-up, open the vent to purge the air from the housing, then refit the plug. For installation and leak testing, see the all-Teflon housing installation, leak test and maintenance SOP.

What is the difference between flare and insert-bead fittings?
A flare fitting opens the tube end into a flare that the nut presses against to seal; an insert-bead fitting slips an inner sleeve (the bead) into the tube end before the nut is tightened. Both are common PFA fittings on high-purity semiconductor lines. Choose the one that matches the fittings already on site; we can confirm compatibility when you enquire.
The bowl nut is PVDF. Does it touch the chemical?
No. The nut only clamps the bowl to the head and sits outside the flow path; the fluid only meets the PFA bowl, head and ports and the PFA jacket of the O-ring. The nut is PVDF because it is stiffer than PFA and deforms less when tightened.
What are the pressure and temperature ratings?
Ask our sales team for the pressure–temperature ratings and outline dimensions when enquiring. PFA softens as temperature rises and the allowable pressure falls with it, so for hot chemicals please tell us the actual operating temperature and pressure.
How is the part number built?
The format is JY-HSC3-capacity-port-O-ring: capacity 05, 10 or 20; port F07 / F10 for 3/4" / 1" flare, B07 / B10 for 3/4" / 1" insert-bead; O-ring P (PFA-encapsulated FKM). For example JY-HSC3-10-F10-P is a housing for a single 10" cartridge with 1" flare fittings.

Further Reading

2026-05-04

Why All Teflon Filter Housings Are Essential in Strong Acid and Alkali Environments: A Materials Science Analysis

Starting from the 485 kJ/mol C-F bond energy, this article explains why PTFE and PFA resist pH 0–14 across all common process chemicals. It dissects the failure mechanisms of 316L stainless steel (passivation collapse, pitting corrosion), PP (swelling in HF), and PVDF (dehydrofluorination in hot alkali), then defines the strict All Teflon specification — housing body, lining, O-ring seals, and fasteners all in fluoropolymer. Covers semiconductor wet benches, pharmaceutical cytotoxic API synthesis, and lithium battery electrolyte filtration, with a practical procurement checklist.

2026-05-04

All Teflon Filter Housing Installation, Leak Testing, and Maintenance SOP

A complete installation-to-maintenance SOP for All Teflon filter housings, covering uncrating cleanliness inspection, correct PTFE-encapsulated FKM O-ring installation (15–25% compression), three-stage cross-pattern bolt torquing (typical 25–50 N·m for 4-inch housings), nitrogen pressure leak testing at 1.1 times operating pressure for 10 minutes, cold flow inspection criteria, and safe shutdown and restart procedures for strong acid and alkali service.

2026-03-16

Filter O-ring Material Selection: FFKM, EPDM, Viton Compared

One failed O-ring negates the whole cartridge. Compare NBR, EPDM, Viton (FKM), Silicone, FFKM across temperature, chemical compatibility, certifications, and 100× cost spread.